3.1.8. Software and Hardware Upgrades
To install application software upgrades, follow the same steps used for the initial software installation (please refer to
LBI-39040, PBX Interface User’s Manual).
For ROM operating system software upgrades, follow the steps below.
1. Execute "shutdn" with the PI console.
2. Execute "status" until no calls are active.
3. Execute "sync" with the PI console.
4. Remove power to the PI.
5. Remove the PIC board and use proper ESD protection.
6. Install new ROM U22 and ROM U30.
7. Replace PIC board.
8. Reapply power.
3.2. INSTALLATION AT SITES
3.2.1. Site Controller
Follow the normal installation procedures found in LBI-38985, EDACS Site Controller Maintenance Manual.
The configuration below is required for the EDACS equipment.
SITE CONTROLLER CONFIGURATION
Personality PROM
With System Manager
Interconnect set to centralized.
Confirmed CTIS calls.
Without System Manager
Interconnect set to centralized.
Confirmed CTIS calls.
Start up wide-area table specifies LID 16383 and each GID allowed to receive inbound
interconnect calls (limit 60 GID).
Site channels wide-area enabled.
The Maximum Interconnect Calls for a site is set based on the maximum number of
concurrent interconnect calls appropriate for the site.