Ericsson LBI-39001 Manuale dell'Operatore Pagina 11

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 46
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 10
11
2.2.4.2. Link GETC Uplink/Downlink Requirements
Hardware Turbo Hardware Revision
Downlink Yes Rev. F or later for 19D902104
or
any rev. of 19D904266
Uplink No Rev. F or later for 19D902104
or
any rev. of 19D904266
2.2.4.3. SCAT GETC Requirements
Hardware Turbo Hardware Revision
SCAT Yes Rev. F or later for 19D902104
or
any rev. of 19D904266
2.2.5. Jessica Requirements
2.2.5.1. MD110 Requirements
Please refer to LBI-39039, EDACS Jessica PBX Gateway MD110 Configuration Manual, for MD110 requirements.
2.2.5.2. PI Requirements
The PI requirements are as follows:
T1
MUX and MD110 connection ports are 100 ohm balanced.
E1
MUX and MD110 connection ports are 120 ohm balanced.
2.2.5.3. MUX Requirements
The MUX provided with Jessica meets the following requirements:
T1
23 channels of balanced 600 ohm 4-wire audio (no signaling required).
1.544 Mb/s 100 ohm aggregate interface.
T1 framing is extended superframe (ESF).
T1 line coding is B8ZS.
120 VAC 50/60 Hz or 240 VAC 50/60 Hz is preferred.
The unit will mount in a 19-inch rack.
CCITT: G.703, G.704, G.711 (u-Law), G.733, G.734, and G.824.
FCC Part 15 Class B approval is required.
CSA and UL approval are required.
Vedere la pagina 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 45 46

Commenti su questo manuale

Nessun commento