13. Return to LINE using the RTN key.
14. Verify that the display on ACU(DS1) indicates either ND4E or LINE.
If ND4E is indicated, go to step 15.
If LINE is indicated, go to step 17.
15. Press the or key to indicate LINE.
16. Verify that the display on ACU(DS1) indicates LINE, and go to step 17.
17. Press the ENTR key.
18. Verify that the display on ACU(DS1) indicates CLK, and press the ENTR key.
19. Verify that the display on ACU(DS1) indicates EXTI.
20. Press the key twice to indicate CLKA, and press the ENTR key.
21. Verify that the display on ACU(DS1) indicates NDDS or DDS.
22. Select NDDS or DDS by using the or key, and press the ENTR key.
If NDDS is selected, go to step 23.
If DDS is selected, to step 25.
23. Verify that the display on ACU(DS1) indicates EXT, LOOP, or INT.
24. Note: EXT is applied to use the external clock as the non-DDS clock. LOOP is applied to use the DS1 receive
clock as the non-DDS clock. INT is applied to use the internal clock generated by ND4E as the non-DDS clock.
The factory default setting is INT.
Set one clock out of EXT, LOOP, or INT by using the or key, press the ENTR key, and then go to step 25.
25. Verify that the display on ACU(DS1) indicates CLK, and press the ENTR key.
26. Verify that the display on ACU(DS1) indicates CLKB.
27. Return to LINE using the RTN key.
28. The procedure is completed.
3.1.4. MD110
Refer to EN/LZB 103 866, Installation MD110/50, for instructions on MD110 installation.
3.1.5. System Manager
Release 1.0 of Jessica has no direct System Manager interface; however, the following configuration information must be
entered at the System Manager.
SYSTEM MANAGER CONFIGURATION
Database
LID/GID must be wide-area enabled to place or receive PSTN calls.
LID/GID must be valid for inbound interconnect.
Site Channels must be wide-area enabled to allow PSTN calls.
Site Channels should not be interconnect enabled. This is for local interconnect only. Enabling
this field for Jessica could result in false alarms.
The Maximum Interconnect Calls for a site is set based on the maximum number of concurrent
interconnect calls appropriate for the site. If the sum of the Maximum Interconnect Calls for all
sites on the Multisite Network exceeds 23/30, interconnect calls may be blocked.
Suggested setting for interconnect hang time is 30 seconds.
Suggested message conversation time limit is 5 minutes.
A site does not have to be created for the PI.
The Centralized Telephone Interconnect default ID is 16, but can be changed to any number
under 32 that is not being used.